Publication : L'utilisation de marges personnalisées dans le traitement du cancer du poumon en radiothérapie
bul.contributor.advisor-authkey | Beaulieu, Luc|=XX4421757 | |
bul.contributor.author-authkey | Germain, François|=XX5006965 | |
bul.description.provenance | flk gj | |
bul.identifier.controlNumber | 1132020674 | |
dc.contributor.advisor | Beaulieu, Luc | |
dc.contributor.author | Germain, François | |
dc.date.accessioned | 2018-04-12T21:49:18Z | |
dc.date.available | 2018-04-12T21:49:18Z | |
dc.date.issued | 2005 | |
dc.date.updated | 2018-04-12T21:49:17Z | |
dc.description.abstract | L’utilisation de marges personnalisées dans le traitement du cancer du poumon en radiothérapie : analyse des mouvements physiologiques et des impacts dosimétriques OBJECTIFS : Le but de cette étude est d’analyser les mouvements physiologiques et leurs impacts dosimétriques lors de la planification de traitements en radiothérapie par tomodensitométrie thoracique (TDM). MÉTHODES : Il s’agit d’une étude de 15 patients. Des plans de radiothérapie conforme tridimensionnelle (3D-CRT) ont été utilisés. Un plan de référence a été fait et comparé à des plans utilisant des marges personnalisées (obtenue par 5 TDM). Des analyses volumétriques et dosimétriques ont été faites. RÉSULTATS : Les volumes obtenus progressent rapidement avec la fusion de TDM. Lorsqu’une couverture semblable est obtenue, le volume cible est moindre et l’irradiation pulmonaire est discrètement réduite. CONCLUSION : Malgré les avantages d’une marge personnalisée, elle ne produit qu’un avantage clinique limité. Toutes les techniques augmentant le volume total pour inclure les mouvements devraient en venir à des conclusions semblables. | fr |
dc.description.abstract | Individualized margins in radiotherapy planning of lung cancer: analysis of physiological movements and their dosimetric impacts OBJECTIVE: This study is an analysis of physiological movements and their dosimetric impacts when a single thoracic CT-scan is used for treatment planning purposes in radiation oncology. METHODS: This is a study of 15 patients. Three-dimensional conformal radiation therapy was (3D-CRT) was used. A reference clinical plan was constructed and compared with plans using individualized margins (obtained by using five CT-scans). Volumetric and dosimetric analyses were made for each. RESULTS: The total volume occupied by GTV progressed quickly with the fusion of CT-scans. For a similar coverage, target volume was smaller and lung irradiation was slightly decreased. CONCLUSIONS: Even if the individualized margin was used, it produced a limited clinical advantage. All techniques that increase total volume with an aim to include more movements should come to similar conclusions. | en |
dc.format.extent | 70 p. | |
dc.identifier.bac | TC-QQLA-23261 | |
dc.identifier.other | 23261 | |
dc.identifier.uri | http://hdl.handle.net/20.500.11794/19429 | |
dc.language | fre | |
dc.rights | http://purl.org/coar/access_right/c_abf2 | |
dc.subject.classification | W 4 UL 2005 | |
dc.subject.rvm | Poumons -- Cancer -- Radiothérapie | fr_CA |
dc.subject.rvm | Poumons -- Cancer -- Tomographie | fr_CA |
dc.subject.rvm | Dosimétrie en radiothérapie | fr_CA |
dc.title | L'utilisation de marges personnalisées dans le traitement du cancer du poumon en radiothérapie | fr_CA |
dc.type | mémoire de maîtrise | |
dc.type.legacy | COAR1_1::Texte::Thèse::Mémoire de maîtrise | fr |
dcterms.publisher.location | Québec | |
dspace.accessstatus.time | 2022-11-15 23:13:20 | |
dspace.entity.type | Publication | |
etdms.degree.grantor | Université Laval | fr_CA |
etdms.degree.name | Mémoire. Médecine | fr_CA |
etdms.degree.name | Mémoire. Médecine expérimentale | fr_CA |
relation.isAdvisorOfPublication | ceb09268-18a0-4be1-91a1-7b66e84d31b4 | |
relation.isAdvisorOfPublication.latestForDiscovery | ceb09268-18a0-4be1-91a1-7b66e84d31b4 | |
relation.isAuthorOfPublication | 1e7b1244-1eca-429f-ac89-16e4afc105bb | |
relation.isAuthorOfPublication.latestForDiscovery | 1e7b1244-1eca-429f-ac89-16e4afc105bb | |
relation.isResourceTypeOfPublication | 5324f3cf-6e18-4f28-a339-115c99bd2b34 | |
relation.isResourceTypeOfPublication.latestForDiscovery | 5324f3cf-6e18-4f28-a339-115c99bd2b34 |
Fichiers
Bundle original
1 - 1 sur 1
En cours de chargement...
- Nom :
- 23261.pdf
- Taille :
- 1.29 MB
- Format :
- Adobe Portable Document Format
- Description :
- Texte