Publication :
L'utilisation de marges personnalisées dans le traitement du cancer du poumon en radiothérapie

bul.contributor.advisor-authkeyBeaulieu, Luc|=XX4421757
bul.contributor.author-authkeyGermain, François|=XX5006965
bul.description.provenanceflk gj
bul.identifier.controlNumber1132020674
dc.contributor.advisorBeaulieu, Luc
dc.contributor.authorGermain, François
dc.date.accessioned2018-04-12T21:49:18Z
dc.date.available2018-04-12T21:49:18Z
dc.date.issued2005
dc.date.updated2018-04-12T21:49:17Z
dc.description.abstractL’utilisation de marges personnalisées dans le traitement du cancer du poumon en radiothérapie : analyse des mouvements physiologiques et des impacts dosimétriques OBJECTIFS : Le but de cette étude est d’analyser les mouvements physiologiques et leurs impacts dosimétriques lors de la planification de traitements en radiothérapie par tomodensitométrie thoracique (TDM). MÉTHODES : Il s’agit d’une étude de 15 patients. Des plans de radiothérapie conforme tridimensionnelle (3D-CRT) ont été utilisés. Un plan de référence a été fait et comparé à des plans utilisant des marges personnalisées (obtenue par 5 TDM). Des analyses volumétriques et dosimétriques ont été faites. RÉSULTATS : Les volumes obtenus progressent rapidement avec la fusion de TDM. Lorsqu’une couverture semblable est obtenue, le volume cible est moindre et l’irradiation pulmonaire est discrètement réduite. CONCLUSION : Malgré les avantages d’une marge personnalisée, elle ne produit qu’un avantage clinique limité. Toutes les techniques augmentant le volume total pour inclure les mouvements devraient en venir à des conclusions semblables.fr
dc.description.abstractIndividualized margins in radiotherapy planning of lung cancer: analysis of physiological movements and their dosimetric impacts OBJECTIVE: This study is an analysis of physiological movements and their dosimetric impacts when a single thoracic CT-scan is used for treatment planning purposes in radiation oncology. METHODS: This is a study of 15 patients. Three-dimensional conformal radiation therapy was (3D-CRT) was used. A reference clinical plan was constructed and compared with plans using individualized margins (obtained by using five CT-scans). Volumetric and dosimetric analyses were made for each. RESULTS: The total volume occupied by GTV progressed quickly with the fusion of CT-scans. For a similar coverage, target volume was smaller and lung irradiation was slightly decreased. CONCLUSIONS: Even if the individualized margin was used, it produced a limited clinical advantage. All techniques that increase total volume with an aim to include more movements should come to similar conclusions.en
dc.format.extent70 p.
dc.identifier.bacTC-QQLA-23261
dc.identifier.other23261
dc.identifier.urihttp://hdl.handle.net/20.500.11794/19429
dc.languagefre
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.subject.classificationW 4 UL 2005
dc.subject.rvmPoumons -- Cancer -- Radiothérapiefr_CA
dc.subject.rvmPoumons -- Cancer -- Tomographiefr_CA
dc.subject.rvmDosimétrie en radiothérapiefr_CA
dc.titleL'utilisation de marges personnalisées dans le traitement du cancer du poumon en radiothérapiefr_CA
dc.typemémoire de maîtrise
dc.type.legacyCOAR1_1::Texte::Thèse::Mémoire de maîtrisefr
dcterms.publisher.locationQuébec
dspace.accessstatus.time2022-11-15 23:13:20
dspace.entity.typePublication
etdms.degree.grantorUniversité Lavalfr_CA
etdms.degree.nameMémoire. Médecinefr_CA
etdms.degree.nameMémoire. Médecine expérimentalefr_CA
relation.isAdvisorOfPublicationceb09268-18a0-4be1-91a1-7b66e84d31b4
relation.isAdvisorOfPublication.latestForDiscoveryceb09268-18a0-4be1-91a1-7b66e84d31b4
relation.isAuthorOfPublication1e7b1244-1eca-429f-ac89-16e4afc105bb
relation.isAuthorOfPublication.latestForDiscovery1e7b1244-1eca-429f-ac89-16e4afc105bb
relation.isResourceTypeOfPublication5324f3cf-6e18-4f28-a339-115c99bd2b34
relation.isResourceTypeOfPublication.latestForDiscovery5324f3cf-6e18-4f28-a339-115c99bd2b34
Fichiers
Bundle original
Voici les éléments 1 - 1 sur 1
En cours de chargement...
Vignette d'image
Nom :
23261.pdf
Taille :
1.29 MB
Format :
Adobe Portable Document Format
Description :
Texte