Pour savoir comment effectuer et gérer un dépôt de document, consultez le « Guide abrégé – Dépôt de documents » sur le site Web de la Bibliothèque. Pour toute question, écrivez à corpus@ulaval.ca.
 

Publication :
Utilisation de la radioluminescence pour la conception de dosimètres optiques déformables

bul.contributor.advisor-marc100Beaulieu, Luc|=$aBeaulieu, Luc,$d1969-
bul.contributor.advisor-marc100Archambault, Louis|=$aArchambault, Louis,$d1979-
bul.contributor.author-marc100Cloutier, Emily|=$aCloutier, Emily
bul.date.reception2022-06-29
bul.description.alirecat202207 elcou28
bul.faculteFaculté des sciences et de génie.
bul.identifier.controlNumber1334984541
bul.identifier.uuid7bf396c9-d84a-4627-81c1-e148eeef08c0
dc.contributor.advisorBeaulieu, Luc
dc.contributor.advisorArchambault, Louis
dc.contributor.advisorArchambault, Louis
dc.contributor.advisorBeaulieu, Luc
dc.contributor.authorCloutier, Emily
dc.contributor.authorCloutier, Emily
dc.date.accessioned2022-07-11T07:07:12Z
dc.date.available2022-07-11T07:07:12Z
dc.date.issued2022
dc.date.updated20230207
dc.description.abstractLes traitements modernes de radiothérapie administrent la dose nécessaire à l'éradication de la région tumorale par un enchaînement complexe de faisceaux personnalisés selon l'anatomie de chaque patient. La distribution de dose résultante présente donc de forts gradients qui visent à maximiser l'irradiation de la maladie tout en limitant l'exposition des tissus sains. Or, les déformations et mouvements anatomiques que présentent certains patients viennent modifier la géométrie attendue et peuvent réduire la qualité escomptée du traitement. Dans ce contexte, le besoin d'outils permettant la quantification de la dose en présence de déformations est grandissant. Utilisant à profit les qualités uniques démontrées des dosimètres optiques, la thèse présentée vise le développement d'une nouvelle génération de dosimètres pensée pour la dosimétrie déformable. Entre autres, il sera montré que le dosimètre développé permet une mesure simultanée de la dose et de la déformation, ce qui ouvre la voie à la validation expérimentale d'algorithmes de recalage d'images déformables. Les contributions de la thèse se déploient principalement selon trois volets : la caractérisation des défis liés à l'utilisation de différentes sources de signaux radioluminescents, en particulier la radiation Cherenkov et la scintillation ; le développement de techniques de détection adaptées, telles que l'imagerie polarisée, l'imagerie spectrale et la triangulation stéréoscopique ; puis le développement d'un dosimètre déformable utilisant ces signaux pour la mesure simultanée de la dose et de la déformation. D'abord, la directionalité de l'émission Cherenkov a été caractérisée de pair avec l'imagerie polarisée. Le rayonnement Cherenkov est une émission lumineuse directement produite dans l'eau, le milieu de référence, suite à son irradiation. Or, les photons optiques sont émis selon un cône dont l'angle et l'orientation sont déterminés par l'énergie du faisceau et sa direction, lesquels varient grandement dans un fantôme. Ainsi, l'imagerie polarisée a été étudiée comme solution à l'utilisation du signal Cherenkov pour des mesures précises de la dose. En utilisant l'imagerie polarisée, la contribution polarisée du signal a été associée à la directionnalité du rayonnement qui a alors pu être corrigée. Ainsi, des écarts lors de mesures de dose atteignant jusqu'à 60% avec les valeurs attendues ont été réduits à moins de 3% en moyenne. Il a d'ailleurs été montré que l'état de polarisation du signal Cherenkov peut être utilisé pour le discriminer d'un signal de scintillation. Ainsi, les deux premières études présentées au sein de cette thèse montrent que des mesures précises (< 3%) de la dose, directement dans l'eau (le milieu de référence), peuvent être réalisées en utilisant le signal Cherenkov combiné à l'imagerie polarisée. Concernant l'utilisation de caméras pour la mesure de signaux radioluminescents, il a été montré qu'il est possible d'allier la grande résolution spatiale de ces photodétecteurs à une résolution spectrale. Les caméras polychromatiques utilisant un patron de Bayer, par exemple, collectent la lumière avec plusieurs milliers de pixels sur lesquels des filtres colorés sont apposés de sorte à former une mosaïque. Ainsi, ces caméras mesurent la lumière selon un canal rouge, vert et bleu. En utilisant les techniques de dématriçage appropriées, il est possible d'interpoler l'information spectrale manquante à chaque pixel. Ainsi, le formalisme hyperspectral, initialement développé pour des mesures en un point, peut être appliqué à des mesures de plus grande résolution spatiale. Ainsi, il a été montré que l'utilisation d'un kernel bilinéaire pour le dématriçage d'une caméra polychromatique utilisant un filtre de Bayer permet d'isoler les signaux Cherenkov et de scintillation avec une précision de 1%. Enfin, un dosimètre déformable permettant la mesure simultanée de la dose et de la déformation a été développé. Le système comprend un fantôme cylindrique transparent au sein duquel un réseau de 19 scintillateurs a été intégré. Le système comprend également un ensemble de 2 paires de caméras stéréoscopiques qui permet le suivi en 3D de la position des extrémités de chacun des scintillateurs. En conséquence, le système permet le suivi de la déformation avec une exactitude et une précision de respectivement 0.08 mm et 0.3 mm. Le suivi 3D de la position permet aussi la correction des variations de signal qui ne sont pas proportionnelles à la dose, mais plutôt au couplage des fibres avec la caméra. Le dosimètre a également permis la mesure de la dose en accord à 1% près avec celle prédite par un logiciel de planification de traitement et un système dosimétrique complémentaire. Ainsi, la thèse a permis le développement d'un premier dosimètre mesurant simultanément la dose et la déformation, permettant une comparaison avec un algorithme de recalage d'image déformable. Ce faisant, l'exploration d'une nouvelle voie d'application de la scintillation a, de plus, mené à l'avancement des connaissances en dosimétrie optique.fr
dc.description.abstractModern radiotherapy treatments deliver the dose to the target through a complex sequence of beams customized to the anatomy of each patient. The resulting dose distribution therefore has strong gradients that aim to maximize disease irradiation while limiting exposure of healthy tissue. However, the anatomical deformations and movements that some patients present modify the expected geometry and may potentially reduce the quality of the treatment. In this context, there is a growing need for tools able of measuring dose in the presence of deformations. Taking advantage of the unique qualities of optical dosimeters, the presented thesis aims at developing a new generation of dosimeters designed for deformable dosimetry. Enabling simultaneous measurements of dose and deformation, this dosimeter could also be used for the validation of deformable image registration algorithms. The contributions of the thesis are threefold: the characterization of the challenges related to the use of different sources of radioluminescent signals, in particular Cherenkov radiation and scintillation; the development of appropriate detection techniques, such as polarized imaging, spectral imaging and stereo triangulation; and then the development of a deformable dosimeter using these signals for the simultaneous measurement of dose and deformation. First, the directionality of Cherenkov emission was characterized using polarized imaging. Cherenkov radiation is a light emission directly produced in water, the reference medium for beam monitoring. Cherenkov photons are emitted in a cone whose angle and orientation are determined by the beam energy and direction, which vary greatly in a phantom. Thus, polarized imaging has been investigated as a solution enabling the use of Cherenkov emission for accurate dose measurements. By using polarization imaging, the polarized contribution of the signal was associated with the directionality of the radiation, which could then be corrected. Thus, deviations in dose measurements previously up to 60% from the expected values were reduced under 3% on average. It has also been shown that the polarization state of the Cherenkov signal can be used to discriminate it from a scintillation signal. Thus, the first two studies presented in this thesis show that accurate measurements, without disturbing the reference medium, can be made using the Cherenkov signal combined with polarization imaging. Concerning the use of cameras for the measurement of radioluminescent signals, it has been shown that it is possible to combine the high spatial resolution of these photodetectors with a spectral resolution. Polychromatic cameras using a Bayer pattern, for example, collect light with several thousand pixels on which colored filters are affixed to form a mosaic. Thus, these cameras measure the light according to a red, green and blue channel. By using appropriate demosaicing techniques, it is possible to interpolate the missing spectral information at each pixel. Thus, the hyperspectral formalism, initially developed for single point measurements, can be applied to higher spatial resolution measurements. Among others, the use of a bilinear kernel for dematrixing a polychromatic camera using a Bayer filter allows to isolate Cherenkov and scintillation signals with an accuracy of 1%. Finally, a deformable dosimeter allowing the simultaneous measurement of dose and deformation has been developed. The system includes a transparent cylindrical phantom in which an array of 19 scintillators has been integrated. The system also includes a set of 2 pairs of stereo cameras that allows the 3D tracking of the position of each scintillator ends. As a result, the system allows the 3D tracking of the deformation with an accuracy and accuracy of 0.08 mm and 0.3 mm respectively. This 3D position tracking also allows the correction of signal variations that are not proportional to the dose, but rather to the coupling of the fibers with the camera. The dosimeter also allowed measurement of the dose in agreement within 1% of the dose predicted by a treatment planning software and a complementary dosimetric system. Thus, the thesis allowed the development of a first dosimeter measuring simultaneously the dose and the deformation, allowing a comparison with a deformable image registration algorithm. In doing so, the exploration of a new application of scintillation has also led to the advancement of knowledge in optical dosimetryen
dc.format.extent1 ressource en ligne (xx, 194 pages)
dc.identifier.bacTC-QQLA-38107
dc.identifier.nothese38107
dc.identifier.other38107
dc.identifier.urihttp://hdl.handle.net/20.500.11794/73768
dc.languagefre
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.subject.rvmLuminescence.fr_CA
dc.subject.rvmDosimètres.fr_CA
dc.subject.rvmRayonnement.fr_CA
dc.titleUtilisation de la radioluminescence pour la conception de dosimètres optiques déformables
dc.typethèse de doctorat
dc.type.legacyCOAR1_1::Texte::Thèse::Thèse de doctoratfr
dcterms.publisher.locationQuébec
dspace.accessstatus.time2024-03-21 20:20:33
dspace.entity.typePublication
etdms.degree.disciplineDoctorat en physique
etdms.degree.grantorUniversité Lavalfr_CA
etdms.degree.namePhilosophiæ doctor (Ph. D.)fr_CA
relation.isAdvisorOfPublicationcb5e8e1e-5258-4287-b359-be6b47c8a461
relation.isAdvisorOfPublicationceb09268-18a0-4be1-91a1-7b66e84d31b4
relation.isAdvisorOfPublication.latestForDiscoverycb5e8e1e-5258-4287-b359-be6b47c8a461
relation.isAuthorOfPublication122ce296-003a-4b65-ba66-cad27ae5df91
relation.isAuthorOfPublication.latestForDiscovery122ce296-003a-4b65-ba66-cad27ae5df91
relation.isResourceTypeOfPublicationea18b676-87ff-47c6-8d0d-fc3b87c36448
relation.isResourceTypeOfPublication.latestForDiscoveryea18b676-87ff-47c6-8d0d-fc3b87c36448

Fichiers

Bundle original
Voici les éléments 1 - 1 sur 1
En cours de chargement...
Vignette d'image
Nom :
38107.pdf
Taille :
31.15 MB
Format :
Adobe Portable Document Format
Description :