Publication :
Preoperative posterior leaflet angle accurately predicts outcome after restrictive mitral valve annuloplasty for ischemic mitral regurgitation

bul.description.provenancedclfr_CA
bul.description.provenancespbfr_CA
bul.rights.dateAccepPubl2007-02-13fr_CA
bul.rights.periodeEmbargoforeverfr_CA
bul.rights.raisonEmbargoInfiniPour que le document soit diffusé en libre accès, en accord avec le délai prescrit par l’éditeur, il faudrait déposer la version acceptée par le comité de lecture, incluant toutes les corrections, sans la mise en page de la revue.
bul.rights.typeDatedatePublicationfr_CA
dc.audienceCardiologuesfr_CA
dc.audienceMédecinsfr_CA
dc.audienceProfesseurs (Enseignement supérieur)fr_CA
dc.audienceÉtudiantsfr_CA
dc.audienceDoctorantsfr_CA
dc.contributor.authorSénéchal, Mario
dc.contributor.authorMagne, Julien
dc.contributor.authorHachicha, Zeineb
dc.contributor.authorPibarot, Philippe
dc.contributor.authorDumesnil, Jean G.
dc.contributor.authorDagenais, François
dc.date.accessioned2016-07-11T12:41:50Z
dc.date.available9999-12-31
dc.date.issued2007-02-13
dc.description.abstractBACKGROUND: Ischemic mitral regurgitation (MR) often persists after restrictive mitral valve annuloplasty, in which case it is associated with worse clinical outcomes. The goal of the present study was to determine whether persistence of MR and/or clinical outcome could be predicted from preoperative analysis of mitral valve configuration METHODS AND RESULTS : In 51 consecutive patients undergoing restrictive annuloplasty for ischemic MR, posterior leaflet (PL) angle, anterior leaflet angle, coaptation distance, and tenting area were quantified by echocardiography before surgery (6+/-3 days), and MR severity was assessed before and early after surgery (9+/-4 days). Postoperatively, persistence of mild to moderate MR (vena contracta > 3 mm) was observed in 11 (22%) of the patients. The best predictor of postoperative persistence of MR was a PL angle > or = 45 degrees (sensitivity 100%, specificity 97%, positive predictive value 92%, negative predictive value 100%). Patients with persistent MR had markedly lower 3-year event-free survival (26+/-20%) compared with those with nonpersistent MR (75+/-12%, P=0.01). Preoperative presence of a PL angle > or = 45 degrees also was associated with a markedly lower 3-year event-free survival (22+/-17% versus 76+/-12%; P<0.001). CONCLUSIONS: In patients undergoing restrictive annuloplasty for ischemic MR, persistence of MR and 3-year event-free survival can accurately be predicted by preoperative analysis of mitral valve configuration. Patients with a PL angle > or = 45 degrees (ie, with high PL restriction) should thus be considered poor candidates for this procedure, and concomitant or alternative procedures should be contemplated.fr_CA
dc.identifier.doi10.1161/CIRCULATIONAHA.106.649236fr_CA
dc.identifier.issn0009-7322fr_CA
dc.identifier.pubmed17283262fr_CA
dc.identifier.urihttp://hdl.handle.net/20.500.11794/8428
dc.languageengfr_CA
dc.publisherAmerican Heart Associationfr_CA
dc.rightshttp://purl.org/coar/access_right/c_16ec
dc.subjectMitral valvefr_CA
dc.subjectEchocardiographyfr_CA
dc.subjectIschemiafr_CA
dc.subjectRegurgitationfr_CA
dc.subject.rvmAnnuloplastie mitralefr_CA
dc.subject.rvmInsuffisance mitralefr_CA
dc.subject.rvmIschémiefr_CA
dc.titlePreoperative posterior leaflet angle accurately predicts outcome after restrictive mitral valve annuloplasty for ischemic mitral regurgitationfr_CA
dc.typearticle de recherche
dc.type.legacyCOAR1_1::Texte::Périodique::Revue::Contribution à un journal::Article::Article de recherche
dcterms.bibliographicCitationCirculation, Vol. 115 (6), 782-791 (2007)fr_CA
dspace.accessstatus.time2023-05-25 18:17:17
dspace.entity.typePublication
relation.isAuthorOfPublication1a770d89-f1ab-4702-abf8-f1f2fe6d5231
relation.isAuthorOfPublication5207bb81-148c-4f58-bef0-e7c71081fbb2
relation.isAuthorOfPublication7c9dba03-31ee-469f-ab38-9b3c08a5d2f1
relation.isAuthorOfPublicationd7348299-5a25-4b46-9956-ec002b869afa
relation.isAuthorOfPublicationd91d0861-9eeb-4ec7-bb17-119c860be62c
relation.isAuthorOfPublicatione2723694-f4c6-43a9-8bc9-19c67b4ab7e4
relation.isAuthorOfPublication.latestForDiscovery1a770d89-f1ab-4702-abf8-f1f2fe6d5231
relation.isResourceTypeOfPublication4c433ef5-3937-4530-8252-cca17d715747
relation.isResourceTypeOfPublication.latestForDiscovery4c433ef5-3937-4530-8252-cca17d715747
rioxxterms.projectMOP 67123fr_CA
rioxxterms.project.funder-nameirscfr_CA
rioxxterms.versionVersion of Record (VoR)fr_CA
rioxxterms.version-of-recordhttps://doi.org/10.1161/CIRCULATIONAHA.106.649236fr_CA
Fichiers
Bundle original
Voici les éléments 1 - 1 sur 1
En cours de chargement...
Vignette d'image
Nom :
Magne2007-10053.pdf
Taille :
685.85 KB
Format :
Adobe Portable Document Format
Description :