Publication :
Caractérisation et optimisation d'un détecteur à scintillation à 2 points

bul.contributor.advisor-authkeyBeaulieu, Luc|=XX4421757
bul.contributor.advisor-authkeyBeddar, Sam|=NO2015152075
bul.contributor.author-authkeyDuguay-Drouin, Patricia|=XX4893664
bul.description.provenanceec
bul.identifier.controlNumber1132035156
dc.contributor.advisorBeddar, Sam
dc.contributor.advisorBeaulieu, Luc
dc.contributor.authorDuguay-Drouin, Patricia
dc.date.accessioned2020-01-29T19:02:55
dc.date.available2018-04-24T20:42:08Z
dc.date.issued2016
dc.date.updated2018-04-24T20:42:08Z
dc.description.abstractCe projet de recherche s’inscrit dans le domaine de la dosimétrie à scintillation en radiothérapie, plus précisément en curiethérapie à haut débit de dose (HDR). Lors de ce type de traitement, la dose est délivrée localement, ce qui implique de hauts gradients de dose autour de la source. Le but de ce travail est d’obtenir un détecteur mesurant la dose en 2 points distincts et optimisé pour la mesure de dose en curiethérapie HDR. Pour ce faire, le projet de recherche est séparé en deux études : la caractérisation spectrale du détecteur à 2-points et la caractérisation du système de photodétecteur menant à la mesure de la dose. D’abord, la chaine optique d’un détecteur à scintillation à 2-points est caractérisée à l’aide d’un spectromètre afin de déterminer les composantes scintillantes optimales. Cette étude permet de construire quelques détecteurs à partir des composantes choisies pour ensuite les tester avec le système de photodétecteur multi-point. Le système de photodétecteur est aussi caractérisé de façon à évaluer les limites de sensibilité pour le détecteur 2-points choisi précédemment. L’objectif final est de pouvoir mesurer le débit de dose avec précision et justesse aux deux points de mesure du détecteur multi-point lors d’un traitement de curiethérapie HDR.fr
dc.description.abstractIn high dose rate brachytherapy, the dose is delivered locally to the tumour and due to the inverse square law therefore the source is surrounded by high dose gradient. Thus a small uncertainty in the source position can cause a significant dose discrepancy. This project uses scintillation dosimetry for HDR brachytherapy dose measurement applications. The purpose of this work is to develop a detector able to measure the dose at 2 separate points, and optimize for such HDR brachytherapy applications. This project is divided into two parts: the spectral characterization of a 2-points detector, and the characterization of the photodetector system. First, the 2-points detector’s optical chain is characterized using a spectrometer. This allows to determine the optimal scintillating components and to then build optimal 2-points detectors. Second, the photodetector system is also characterized using the detectors built in the first section of the project. The final goal is to use the multi-points detector for precise and accurate dose measurements for both measuring points during HDR brachytherapy treatments.en
dc.format.extent1 ressource en ligne (xiii, 58 pages)
dc.identifier.bacTC-QQLA-32457
dc.identifier.other32457
dc.identifier.urihttp://hdl.handle.net/20.500.11794/26833
dc.languagefre
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.subject.classificationQC 3.5 UL
dc.subject.rvmCompteurs à scintillationsfr_CA
dc.titleCaractérisation et optimisation d'un détecteur à scintillation à 2 pointsfr_CA
dc.typemémoire de maîtrise
dc.type.legacyCOAR1_1::Texte::Thèse::Mémoire de maîtrisefr
dcterms.publisher.locationQuébec
dspace.accessstatus.time2022-11-15 21:19:23
dspace.entity.typePublication
etdms.degree.grantorUniversité Lavalfr_CA
etdms.degree.nameMémoire. Physiquefr_CA
relation.isAdvisorOfPublication6026538c-5c91-4e4c-ba66-f16562ee3156
relation.isAdvisorOfPublicationceb09268-18a0-4be1-91a1-7b66e84d31b4
relation.isAdvisorOfPublication.latestForDiscovery6026538c-5c91-4e4c-ba66-f16562ee3156
relation.isAuthorOfPublication69040459-1946-4494-bb91-fe5d864a54d4
relation.isAuthorOfPublication.latestForDiscovery69040459-1946-4494-bb91-fe5d864a54d4
relation.isResourceTypeOfPublication5324f3cf-6e18-4f28-a339-115c99bd2b34
relation.isResourceTypeOfPublication.latestForDiscovery5324f3cf-6e18-4f28-a339-115c99bd2b34
Fichiers
Bundle original
Voici les éléments 1 - 1 sur 1
En cours de chargement...
Vignette d'image
Nom :
32457.pdf
Taille :
5.45 MB
Format :
Adobe Portable Document Format
Description :
Texte