Publication :
Validation de mesures d'amplitude d'élévation et d'activité musculaire à l'aide de capteurs sans fil pour l'analyse de mouvements fonctionnels à l'épaule

bul.contributor.advisor-authkeyMercier, Catherine|=XX4470770
bul.contributor.advisor-authkeyRoy, Jean-Sébastien|=XX3848636
bul.contributor.author-authkeyPoitras, Isabelle|=XX5092374
bul.description.provenanceec spb
bul.identifier.controlNumber1132037673
bul.identifier.lot20190904
dc.contributor.advisorRoy, Jean-Sébastien
dc.contributor.advisorMercier, Catherine
dc.contributor.authorPoitras, Isabelle
dc.date.accessioned2019-09-06T23:01:36Z
dc.date.available2019-09-06T23:01:36Z
dc.date.issued2019
dc.date.updated2019-09-06T23:01:36Z
dc.descriptionTableau d'honneur de la Faculté des études supérieures et postdoctorales, 2019-2020
dc.description.abstractL’utilisation de données quantitatives afin de diminuer la prévalence des blessures musculosquelettiques liées au travail est souhaitée et le développement de systèmes portables permettant de mesurer l’amplitude articulaire (capteurs inertiels; IMU) et l’activité musculaire (électromyographie; EMG) pourrait permettre d’obtenir ce type de données. La revue systématique de la littérature sur la validité des capteurs inertiels effectuée dans le cadre de ce mémoire a permis d’identifier un manque d’évidence scientifique pour l’évaluation des mouvements complexes à l’épaule. L’objectif principal de ce mémoire est donc (1) d’évaluer la validité concourante d’IMU (Xsens) dans le calcul d’élévation du bras comparé à un système de capture de mouvements (Vicon) lors de mouvements simples et lors de tâches de manutention; et (2) d’établir la validité discriminante du système d’EMG (Trigno) pour évaluer l’activité musculaire. Méthodologie : Seize sujets ont participé à une séance d’évaluation demandant la réalisation de mouvements simples à l’épaule et de transport de charges (poids et hauteurs de transport variables). Le coefficient de corrélation et l’erreur de mesure (RMSE) ont été calculés afin de comparer les mesures d’amplitude articulaire obtenues à l’aide du Xsens et du Vicon et le root mean square (RMS) ainsi que le pic d’activité musculaire des deltoïdes (antérieurs et moyens) ont été calculés pour déterminer l’effet du poids et de la hauteur (ANOVA à mesures répétées). Résultats : Les coefficients de corrélation entre les amplitudes articulaires obtenues par le Xsens et le Vicon sont élevés (>0,84) et les RMSE sont bas (<11,5°). Un effet significatif du poids et de la hauteur, et un effet d’interaction poids x hauteur ont été observés pour le RMS du deltoïde antérieur (p<0,001) et moyen (p<0,03) et pour le pic d’activité du deltoïde antérieur (p<0,003). Conclusion : L’utilisation combinée du Xsens et du Trigno est un outil intéressant afin d’identifier le niveau de demande de l’emploi, puisqu’ils recueillent des données valides d’amplitude articulaire et d’activité musculaire.fr
dc.description.abstractQuantitative assessments of workplace settings are required to diminish the prevalence of work-related shoulder disorders. Recent development of wearable sensors to record muscle activity (electromyography [EMG]; Trigno, Delsys) as well as shoulder range of motion (inertial measurement unit; MVN, Xsens) could potentially be used for such workplace assessments. A systematic review on the validity and reliability of IMUs performed within this thesis identified a knowledge gap for shoulder joint movements during complex tasks. The primary objective of this thesis was therefore (1) to assess the concurrent validity of the Xsens system for assessment of shoulder range of motion compared to a motion capture system (Vicon) during simple movements and working tasks and (2) to establish the discriminative validity of the Trigno EMG system for the evaluation of muscle activity. Methodology: Sixteen subjects participated in one session in which they performed simple movements and work lifting tasks (different weights and lifting heights). The correlation coefficient (r) and the root mean square error (RMSE) were used to compare the data collected by the Xsens and the Vicon. The root mean square EMG envelope (RMS) and the peak EMG activity of anterior and middle deltoids were used to establish the effect of weight and height (repeated measure ANOVA). Results: The correlation coefficient between joint angles measured with the Xsens and the Vicon was high (>0.84) and the RMSE was low (<12.82°). A significant effect of weight, height and a weight x height interaction effect were observed for the RMS (anterior; p<0.001; middle: p<0.03) and the peak EMG activity (anterior; p<0.003). Conclusion: The combination of an inertial measurement unit system and a wireless EMG is a potentially useful tool to assess physical demand in real work context as it provides valid data on muscular activity and range of motion.en
dc.format.extent1 ressource en ligne (xii, 114 pages)
dc.identifier.bacTC-QQLA-35506
dc.identifier.other35506
dc.identifier.urihttp://hdl.handle.net/20.500.11794/36375
dc.languagefre
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.subject.rvmRéseaux de capteurs sans filfr_CA
dc.subject.rvmArticulation scapulohuméralefr_CA
dc.subject.rvmÉpaule -- Exercices -- Mesurefr_CA
dc.titleValidation de mesures d'amplitude d'élévation et d'activité musculaire à l'aide de capteurs sans fil pour l'analyse de mouvements fonctionnels à l'épaulefr_CA
dc.typemémoire de maîtrise
dc.type.legacyCOAR1_1::Texte::Thèse::Mémoire de maîtrisefr
dcterms.publisher.locationQuébec
dspace.accessstatus.time2022-11-15 21:00:30
dspace.entity.typePublication
etdms.degree.grantorUniversité Lavalfr_CA
etdms.degree.nameMémoire. Médecinefr_CA
etdms.degree.nameMémoire. Sciences cliniques et biomédicalesfr_CA
relation.isAdvisorOfPublication1bf49712-7903-498f-9424-fd41e7593679
relation.isAdvisorOfPublication2f3d8edd-7a0b-4db2-ac7c-2c17714f3077
relation.isAdvisorOfPublication.latestForDiscovery1bf49712-7903-498f-9424-fd41e7593679
relation.isAuthorOfPublication3d7b06b9-6efa-4f82-82bf-bfa0f8228d87
relation.isAuthorOfPublication.latestForDiscovery3d7b06b9-6efa-4f82-82bf-bfa0f8228d87
relation.isResourceTypeOfPublication5324f3cf-6e18-4f28-a339-115c99bd2b34
relation.isResourceTypeOfPublication.latestForDiscovery5324f3cf-6e18-4f28-a339-115c99bd2b34
Fichiers
Bundle original
Voici les éléments 1 - 1 sur 1
En cours de chargement...
Vignette d'image
Nom :
35506.pdf
Taille :
3 MB
Format :
Adobe Portable Document Format
Description :