Pour savoir comment effectuer et gérer un dépôt de document, consultez le « Guide abrégé – Dépôt de documents » sur le site Web de la Bibliothèque. Pour toute question, écrivez à corpus@ulaval.ca.
 

Personne :
Annabi, Mohamed Salah

En cours de chargement...
Photo de profil

Adresse électronique

Date de naissance

Projets de recherche

Structures organisationnelles

Fonction

Nom de famille

Annabi

Prénom

Mohamed Salah

Affiliation

Université Laval. Faculté de médecine

ISNI

ORCID

Identifiant Canadiana

ncf11920679

person.page.name

Résultats de recherche

Voici les éléments 1 - 10 sur 14
  • PublicationRestreint
    Low-flow aortic stenosis : flow rate does not replace but could refine stroke volume index
    (American College of Cardiology Foundation, 2021-03-17) Annabi, Mohamed Salah; Clavel, Marie-Annick
  • PublicationAccès libre
    Transvalvular flow, sex, and survival after valve replacement surgery in patients with severe aortic stenosis
    (Elsevier, 2020-04-28) Bilodeau, Anthony; Guzzetti, Ezequiel; Kalavrouziotis, Dimitri; Zhang, Bin; Couture, Christian; Annabi, Mohamed Salah; Pibarot, Philippe; Clavel, Marie-Annick; Dagenais, François
    Background : The respective impacts of transvalvular flow, gradient, sex, and their interactions on mortality in patients with severe aortic stenosis undergoing surgical aortic valve replacement (AVR) are unknown. Objectives : This study sought to compare the impact of pre-operative flow-gradient patterns on mortality after AVR and to examine whether there are sex differences. Methods : This study analyzed clinical, echocardiographic, and outcome data prospectively collected in 1,490 patients (544 women [37%]), with severe aortic stenosis and preserved left ventricular ejection fraction who underwent AVR. Results : In this cohort, 601 patients (40%) had normal flow (NF) with high gradient (HG), 405 (27%) NF with low gradient (LG), 246 (17%) paradoxical low flow (LF)/HG, and 238 (16%) LF/LG. During a median follow-up of 2.42 years (interquartile range: 1.04 to 4.29 years), 167 patients died. Patients with LF/HG exhibited the highest mortality after AVR (hazard ratio [HR]: 2.01; 95% confidence interval [CI]: 1.33 to 3.03; p < 0.01), which remained significant after multivariate adjustment (HR: 1.96; 95% CI: 1.29 to 2.98; p < 0.01). Both LF/LG and NF/LG patients had comparable outcome to NF/HG (p ≥ 0.47). Optimal thresholds of stroke volume index were obtained for men (40 ml/m2) and women (32 ml/m2). Using these sex-specific cutpoints, paradoxical LF was independently associated with increased mortality in both women (adjusted HR: 2.05; 95% CI: 1.21 to 3.47; p < 0.01) and men (adjusted HR: 1.54; 95% CI: 1.02 to 2.32; p = 0.042), whereas guidelines’ threshold (35 ml/m2) does not. Conclusions : Paradoxical LF/HG was associated with higher mortality following AVR, suggesting that a reduced flow is a marker of disease severity even in patients with HG aortic stenosis. Early surgical AVR (i.e., before gradient attains 40 mm Hg) might be preferable in these patients. Furthermore, the use of sex-specific thresholds (<40 ml/m2 for men and <32 ml/m2 for women) to define low-flow outperforms the guidelines’ threshold of 35 ml/m2 in risk stratification after AVR.
  • PublicationRestreint
    Structural deterioration of transcatheter versus surgical aortic valve bioprostheses in the PARTNER-2 trial
    (Elsevier Biomedical, 2020-10-12) Dahou, Abdellaziz; Guzzetti, Ezequiel; Beaudoin, Jonathan; Annabi, Mohamed Salah; Bernier, Mathieu; Pibarot, Philippe; Clavel, Marie-Annick; Salaun, Erwan; Ternacle, Julien
    BACKGROUND It is unknown whether transcatheter valves will have similar durability as surgical bioprosthetic valves. Definitions of structural valve deterioration (SVD), based on valve related reintervention or death, underestimate the incidence of SVD. OBJECTIVES This study sought to determine and compare the 5-year incidence of SVD, using new standardized definitions based on echocardiographic follow-up of valve function, in intermediate-risk patients with severe aortic stenosis given transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) in the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and registry. METHODS In the PARTNER 2A trial, patients were randomly assigned to receive either TAVR with the SAPIEN XT or SAVR, whereas in the SAPIEN 3 registry, patients were assigned to TAVR with the SAPIEN 3. The primary endpoint was the incidence of SVD, that is, the composite of SVD-related hemodynamic valve deterioration during echocardiographic follow-up and/or SVD-related bioprosthetic valve failure (BVF) at 5 years. RESULTS Compared with SAVR, the SAPIEN-XT TAVR cohort had a significantly higher 5-year exposure adjusted incidence rates (per 100 patient-years) of SVD (1.61 ± 0.24% vs. 0.63 ± 0.16%), SVD-related BVF (0.58 ± 0.14% vs. 0.12 ± 0.07%), and all-cause (structural or nonstructural) BVF (0.81 ± 0.16% vs. 0.27 ± 0.10%) (p ≤ 0.01 for all). The 5-year rates of SVD (0.68 ± 0.18% vs. 0.60 ± 0.17%; p ¼ 0.71), SVD-related BVF (0.29 ± 0.12% vs. 0.14 ± 0.08%; p ¼ 0.25), and all-cause BVF (0.60 ± 0.15% vs. 0.32 ± 0.11%; p ¼ 0.32) in SAPIEN 3 TAVR were not significantly different to a propensity score matched SAVR cohort. The 5-year rates of SVD and SVD-related BVF were significantly lower in SAPIEN 3 versus SAPIEN XT TAVR matched cohorts. CONCLUSIONS Compared with SAVR, the second-generation SAPIEN XT balloon-expandable valve has a higher 5-year rate of SVD, whereas the third-generation SAPIEN 3 has a rate of SVD that was not different from SAVR. (The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves - PII A [PARTNERII A]; NCT01314313; The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - PARTNER II - PARTNERII - S3 Intermediate [PARTNERII S3i]; NCT03222128)
  • PublicationAccès libre
    Mitral regurgitation in low-flow, low-gradient aortic stenosis patients undergoing TAVR : insights from the TOPAS-TAVI registry
    (Elsevier, 2020-02-12) Freitas Ferraz, Afonso; Dahou, Abdellaziz; Lerakis, Stamatios A.; Nombela-Franco, Luis; Rodés-Cabau, Josep; Gilard, Martine; Le Ven, Florent; Cavalcante, João L.; Amat Santos, Ignacio J.; Makkar, Rajendra; Annabi, Mohamed Salah; Herrmann, Howard C.; Pelletier Beaumont, Émilie; Windecker, Stephan; Pibarot, Philippe; Enriquez-Sarano, Maurice; Clavel, Marie-Annick; Cheema, Asim; Ribeiro, Henrique B.; Muñoz, Antonio; García del Blanco, Bruno; Zajarias, Alan; Lisko, John C.; Hayek, Salim; Babaliaros, Vasilis; Gleason, Thomas G.; Chakravarty, Tarun; Szeto, Wilson Y.; Agustin, Alberto de; Serra, Vicenç; Schindler, John Thomas
    Objectives : This study sought to determine the incidence, clinical impact, and changes over time of mitral regurgitation (MR) in patients with low-flow, low-gradient aortic stenosis (LFLG-AS) undergoing transcatheter aortic valve replacement (TAVR). Background : Few data exist on the clinical impact and changes in severity over time of MR in patients with LFLG-AS undergoing TAVR. Methods : A total of 308 TAVR candidates with LFLG-AS were included. Patients were categorized according to MR severity at baseline, and presence of MR improvement at 12-month follow-up. Clinical outcomes were assessed at 1 and 12 months (+ echocardiography), and yearly thereafter. Results : Baseline mild and moderate-to-severe MR were present in 118 (38.3%) and 115 (37.3%) patients, respectively. MR was of functional and mixed etiology in 77.2% and 22.7% of patients, respectively. A total of 131 patients (42.5%) died after a median follow-up of 2 (1 to 3) years. Baseline moderate-or-greater MR had no impact on mortality (hazard ratio [HR]: 1.34; 95% confidence interval [CI]: 0.72 to 2.48) or heart failure hospitalization (HR: 1.02; 95% CI: 0.49 to 2.10). At 1-year follow-up, MR improved in 44.3% of patients and remained unchanged/worsened in 55.7%. The lack of MR improvement was associated with a higher risk of all-cause and cardiac mortality (HR: 2.02; 95% CI: 1.29 to 3.17; HR: 3.03; 95% CI: 1.27 to 7.23, respectively), rehospitalization for cardiac causes (HR: 1.50; 95% CI: 1.04 to 2.15), and an increased overall-mortality/heart failure rehospitalization (HR: 1.94; 95% CI: 1.25 to 3.02). A higher baseline left ventricular end-diastolic diameter and a higher increase in left ventricular ejection fraction were found to be independent predictors of MR improvement at 1-year follow-up (odds ratio: 0.69; 95% CI: 0.51 to 0.94; and odds ratio: 0.81; 95% CI: 0.67 to 0.96, respectively). Conclusions : Most TAVR candidates with LFLG-AS had some degree of MR, of functional origin in most cases. MR improved in about one-half of patients, with larger left ventricular size and a higher increase in left ventricular ejection fraction post-TAVR determining MR improvement over time. The lack of MR improvement at 1 year was associated with poorer outcomes.
  • PublicationRestreint
    Pre- and post-operative stroke volume impact after surgical aortic valve replacement for severe aortic stenosis
    (Elsevier Biomedical, 2020-10-19) Guzzetti, Ezequiel; Poulin, Anthony; Kalavrouziotis, Dimitri; Annabi, Mohamed Salah; Pibarot, Philippe; Clavel, Marie-Annick; Dagenais, François
  • PublicationAccès libre
    Prosthesis-patient mismatch after aortic valve replacement in the PARTNER 2 trial and registry
    (Elsevier, 2021-07-05) Dahou, Abdellaziz; Guzzetti, Ezequiel; Herrmann, Howard C.; Beaudoin, Jonathan; Kodali, Susheel; Annabi, Mohamed Salah; Leipsic, Jonathon; Bernier, Mathieu; Blanke, Philipp; Pibarot, Philippe; Jaber, Wael; Clavel, Marie-Annick; Mack, Michael J.; Salaun, Erwan; Ternacle, Julien; Khalique, Omar K.; Weissman, Neil J.; Douglas, Pamela; Bax, Jeroen; Xu, Ke; Alu, Maria; Rogers, Erin; Leon, Martin; Thourani, Vinod H.; Abbas, Amr E.; Hahn, Rebecca T.
    Objectives This study aimed to compare incidence and impact of measured prosthesis-patient mismatch (PPMM) versus predicted PPM (PPMP) after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR). Background TAVR studies have used measured effective orifice area indexed (EOAi) to body surface area (BSA) to define PPM, but most SAVR series have used predicted EOAi. This difference may contribute to discrepancies in incidence and outcomes of PPM between series. Methods The study analyzed SAVR patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and TAVR patients from the PARTNER 2 SAPIEN 3 Intermediate Risk registry. PPM was classified as moderate if EOAi ≤0.85 cm2/m2 (≤0.70 if obese: body mass index ≥30 kg/m2) and severe if EOAi ≤0.65 cm2/m2 (≤0.55 if obese). PPMM was determined by the core lab–measured EOAi on 30-day echocardiogram. PPMP was determined by 2 methods: 1) using normal EOA reference values previously reported for each valve model and size (PPMP1; n = 929 SAVR, 1,069 TAVR) indexed to BSA; and 2) using normal reference EOA predicted from aortic annulus size measured by computed tomography (PPMP2; n = 864 TAVR only) indexed to BSA. Primary endpoint was the composite of 5-year all-cause death and rehospitalization. Results The incidence of moderate and severe PPMP was much lower than PPMM in both SAVR (PPMP1: 28.4% and 1.2% vs. PPMM: 31.0% and 23.6%) and TAVR (PPMP1: 21.0% and 0.1% and PPMP2: 17.0% and 0% vs. PPMM: 27.9% and 5.7%). The incidence of severe PPMM and severe PPMP1 was lower in TAVR versus SAVR (P < 0.001). The presence of PPM by any method was associated with higher transprosthetic gradient. Severe PPMP1 was independently associated with events in SAVR after adjustment for sex and Society of Thoracic Surgeons score (hazard ratio: 3.18;95% CI: 1.69-5.96; P < 0.001), whereas no association was observed between PPM by any method and outcomes in TAVR. Conclusions EOAi measured by echocardiography results in a higher incidence of PPM following SAVR or TAVR than PPM based on predicted EOAi. Severe PPMP is rare (<1.5%), but is associated with increased all-cause death and rehospitalization after SAVR, whereas it is absent following TAVR.
  • PublicationAccès libre
    Impact of sex and sex hormones on pathophysiology and progression of aortic stenosis in a murine model
    (Physiological reports, 2022-08-27) Fleury, Marie-Ange; Annabi, Mohamed Salah; Voisine, Martine; Hervault, Maxime; Boilard, Anne-Julie; Shen, Mylène; Marette, André; Côté, Nancy; Clavel, Marie-Annick
    The lesions observed in AS have been shown to be sex specific, with women presenting extensive fibrotic remodeling while men developing more calcification deposit. We thus aimed to evaluate the influence of sex and sex hormones on the pathophysiology of aortic valve stenosis (AS) in our mouse model of AS. LDLr-/- ApoB100/100 IGF-II+/- mice (n = 210) were separated in six different groups: (1) intact male (IM), (2) intact female (IF), (3) castrated male (CM), (4) ovariectomized females (OF), (5) CM with testosterone supplementation (CMT), and (6) OF with 17β-estradiol supplementation (OFE). Mice were fed a high-fat/high-sucrose/high-cholesterol diet for 6 months. Hemodynamic progression of AS was followed by transthoracic echocardiography (at 12 and 36 weeks) and analyzed in all mice alive at 36 weeks. Aortic valves were collected for histological and digital droplet PCR* analysis. Increases in peak velocity were comparable in IF and IM (24.2 ± 5.7 vs. 25.8 ± 5.3 cm/s; p = 0.68), but IF presented with less severe AS. Between the three groups of male mice, AS progression was more important in IM (increase in peak velocity: 24.2 ± 5.7 cm/s; p < 0.001) compared to CM (6.2 ± 1.4; p = 0.42), and CMT (15.1 ± 3.5; p = 0.002). In the three groups of female mice, there were no statistical differences in AS progression. Digital PCR analysis revealed an important upregulation of the osteogenic gene RunX2 in IM (p < 0.0001) and downregulation of the pro-calcifying gene ALPL in IF (p < 0.05). Male sex and testosterone play an important role in upregulation of pro-calcifying genes and hemodynamic progression of AS. However, female mice appeared to be protected against calcification, characterized by downregulation of pro-osteogenic genes, but presented a similar AS hemodynamic progression
  • PublicationAccès libre
    Effect of regional upper septal hypertrophy on echocardiographic assessment of left ventricular mass and remodeling in aortic stenosis
    (ScienceDirect, 2020-10-14) Guzzetti, Ezequiel; Garcia, Julio; Larose, Éric; Shen, Mylène; Le Ven, Florent; Bédard, Élisabeth; Capoulade, Romain; Annabi, Mohamed Salah; Pibarot, Philippe; Clavel, Marie-Annick; Tastet, Lionel; Arsenault, Marie
    Background: Transthoracic echocardiography (TTE) is the reference method for evaluation of aortic stenosis (AS), and it is extensively used to quantitate left ventricular (LV) mass and volumes. Regional upper septal hypertrophy (USH) or septal bulge is a frequent finding in patients with AS and may lead to overestimation of LV mass when using linear measurements. The objective of this study was to compare estimates of LV mass obtained by two-dimensional transthoracic echocardiographic LV dimensions measured at different levels of the LV cavity with those obtained by cardiovascular magnetic resonance (CMR). Methods: One hundred six patients (mean age, 63 ± 15 years; 68% men) with AS were included in this subanalysis of the PROGRESSA study. Two-dimensional transthoracic echocardiographic measurements of LV dimensions were obtained at the basal level (BL; as recommended in guidelines), immediately below the septal bulge (BSB), and at a midventricular level (ML). Regional USH was defined as a basal interventricular septal thickness ≥ 13 mm and >1.3 times the thickness of the septal wall at the ML. Agreement between transthoracic echocardiographic and CMR measures was evaluated using Bland-Altman analysis. Results: The distribution of AS severity was mild in 23%, moderate in 57%, and severe in 20% of patients. Regional USH was present in 28 patients (26%). In the whole cohort, two-dimensional TTE overestimated LV mass (bias: BL, +60 ± 31 g; BSB, +59 ± 32 g; ML, +54 ± 32 g; P = .02). The biplane Simpson method slightly but significantly underestimated LV end-diastolic volume (bias -10 ± 20 mL, P < .001) compared with CMR. Overestimation of LV mass was more marked in patients with USH when measuring at the BL and was significantly lower when measuring LV dimensions at the ML (P < .025 vs BL and BSB). Conclusions: Two-dimensional TTE systematically overestimated LV mass and underestimated LV volumes compared with CMR. However, the bias between TTE and CMR was less important when measuring at the ML. Measurements at the BL as suggested in guidelines should be avoided, and measurements at the ML should be preferred in patients with AS, especially in those with USH.
  • PublicationRestreint
    Sex-differences in echocardiographic assessment of aortic valve in young adult LDLr−/−/ApoB100/100/IGF-II+/− mice
    (Elsevier, 2020-08-27) Clisson, Marine; Côté, Nancy; Fleury, Marie-Ange; Shen, Mylène; Voisine, Martine; Marette, André; Hervault, Maxime; Annabi, Mohamed Salah; Clavel, Marie-Annick; Boilard, Anne-Julie; Ong, Géraldine
    Background LDLr−/−/ApoB100/100/IGF-II+/− mice are used as a calcific aortic valve disease (CAVD) model. However, normal aortic valve hemodynamics i.e. remotely from CAVD onset and the sex-related differences are poorly known. Methods and results Four groups of mice, intact males (IM, n = 49) and females (IF, n = 50), castrated males (CxM, n = 79) and ovariectomized females (OxF: 73), underwent a Doppler-echocardiography at 12 weeks of age. Gonadectomy was performed at 8 weeks. Aortic valve assessment using effective orifice area (EOA, using the continuity equation) and peak aortic transvalvular velocity (VPeak) was feasible in 89% of the mice with good to excellent reliability (intraclass correlation coefficients ranging from 0.90 to 0.98, p < 0.001). Mean VPeak was 104 ± 17 cm/s and mean EOA was 1.18*10−2 ± 0.22*10−2 cm2. EOA indexed to body surface area was 1.5 ± 0.3 cm2/m2. The 95th percentile of Vpeak was 132 cm/s and the 5th percentile of indexed EOA was 1.0 cm2/m2. Interestingly, IM had the highest VPeak (114 ± 14 cm/s) vs each of the other groups (CxM: 106 ± 19 cm/s, OxF: 97 ± 13 cm/s and IF: 96 ± 12 cm/s, ANOVA and corrected p < 0.001). This was mostly explained by a higher stroke volume (ANOVA and corrected p < 0.001) in IM compared to other groups. There were no major sex-differences in ventricular systolic function parameters. Conclusion In LDLr−/−/ApoB100/100/IGF-II CAVD mice model, an aortic EOA <0.8*10−2 cm2 (or indexed EOA <1.0cm2/m2), and a peak aortic valve velocity > 132 cm/s may be proposed as thresholds to define CAVD. Intact male mice appear to have higher velocities.
  • PublicationAccès libre
    Multimodality imaging for discordant low-gradient aortic stenosis : assessing the valve and the myocardium
    (Frontiers Media S.A., 2020-12-03) Guzzetti, Ezequiel; Annabi, Mohamed Salah; Pibarot, Philippe; Clavel, Marie-Annick
    Aortic stenosis (AS) is a disease of the valve and the myocardium. A correct assessment of the valve disease severity is key to define the need for aortic valve replacement (AVR), but a better understanding of the myocardial consequences of the increased afterload is paramount to optimize the timing of the intervention. Transthoracic echocardiography remains the cornerstone of AS assessment, as it is universally available, and it allows a comprehensive structural and hemodynamic evaluation of both the aortic valve and the rest of the heart. However, it may not be sufficient as a significant proportion of patients with severe AS presents with discordant grading (i.e., an AVA ≤1 cm2 and a mean gradient