Personne :
Lemieux, Jérôme

En cours de chargement...
Photo de profil
Adresse électronique
Date de naissance
Projets de recherche
Structures organisationnelles
Fonction
Nom de famille
Lemieux
Prénom
Jérôme
Affiliation
Institut universitaire de cardiologie et de pneumologie de Québec, Université Laval
ISNI
ORCID
Identifiant Canadiana
ncf11892777
person.page.name

Résultats de recherche

Voici les éléments 1 - 1 sur 1
En cours de chargement...
Vignette d'image
PublicationRestreint

Usefulness of TEE as the primary imaging technique to guide transcatheter transapical aortic valve implantation

2011-02-01, Bertrand, Olivier, Lemieux, Jérôme, Dumont, Éric, De Larochellière, Robert, Côté, Mélanie, Villeneuve, Jacques, Rodés-Cabau, Josep, Bergeron, Sébastien, Bagur, Rodrigo Hernan, Doyle, Daniel, Pibarot, Philippe

Objectives: The aim of this study was to: 1) determine the usefulness of transesophageal echocardiography (TEE) as the primary technique to guide transapical (TA) transcatheter aortic valve implantation (TAVI); and 2) to compare TEE with angiography as the primary imaging modality for TA-TAVI guidance. Background: TEE has been routinely used as an adjunct to angiography during TA-TAVI procedures, but very few data exist on the use of TEE as the primary imaging technique guiding TA-TAVI. Methods: One hundred consecutive high-risk patients (mean age 79 ± 9 years, mean logistic EuroSCORE: 25.8 ± 17.6%) who underwent TA-TAVI in our center were included. The Edwards valve was used in all cases, and all procedures were performed in an operating room without hybrid facilities. The TA-TAVI was primarily guided by angiography in the first 25 patients (A-TAVI group) and by TEE in the last 75 patients (TEE-TAVI group). Procedural, 30-day, and follow-up results were evaluated. Results: No differences were observed between groups at baseline except for a higher (p = 0.001) prevalence of moderate or severe mitral regurgitation in the TEE-TAVI group. The procedure was successful in 97.3% and 100% of the patients in the TEE-TAVI and A-TAVI groups, respectively (p = 1.0), and a lower contrast volume was used in the TEE-TAVI group (12 [5 to 20] ml vs. 40 [20 to 50] ml, p < 0.0001). There were no differences between groups in the occurrence of valve malposition needing a second valve (TEE-TAVI: 5.3%; A-TAVI: 4%; p = 1.0) or valve embolization (TEE-TAVI: 1.3%; A-TAVI: 4%; p = 0.44). The results regarding post-procedural valve hemodynamic status and aortic regurgitation were similar between groups. The survival rates at 30-day and 1-year follow-up were 87% and 75% in the TEE-group and 88% and 84% in the A-TAVI group, respectively (log-rank = 0.49). Conclusions: TEE-TAVI was associated with similar acute and midterm results as A-TAVI and significantly reduced contrast media use during the procedures. These results suggest the feasibility and safety of performing TA-TAVI procedures in an operating room without hybrid facilities, but larger studies are needed to confirm these findings.