Voici les éléments 1 - 6 sur 6
  • PublicationRestreint
    Measuring progression of aortic stenosis : computed tomography versus echocardiography
    (BMJ Pub. Group, 2020-10-09) Guzzetti, Ezequiel; Clavel, Marie-Annick
  • PublicationRestreint
    Structural deterioration of transcatheter versus surgical aortic valve bioprostheses in the PARTNER-2 trial
    (Elsevier Biomedical, 2020-10-12) Dahou, Abdellaziz; Guzzetti, Ezequiel; Beaudoin, Jonathan; Annabi, Mohamed Salah; Bernier, Mathieu; Pibarot, Philippe; Clavel, Marie-Annick; Salaun, Erwan; Ternacle, Julien
    BACKGROUND It is unknown whether transcatheter valves will have similar durability as surgical bioprosthetic valves. Definitions of structural valve deterioration (SVD), based on valve related reintervention or death, underestimate the incidence of SVD. OBJECTIVES This study sought to determine and compare the 5-year incidence of SVD, using new standardized definitions based on echocardiographic follow-up of valve function, in intermediate-risk patients with severe aortic stenosis given transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) in the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and registry. METHODS In the PARTNER 2A trial, patients were randomly assigned to receive either TAVR with the SAPIEN XT or SAVR, whereas in the SAPIEN 3 registry, patients were assigned to TAVR with the SAPIEN 3. The primary endpoint was the incidence of SVD, that is, the composite of SVD-related hemodynamic valve deterioration during echocardiographic follow-up and/or SVD-related bioprosthetic valve failure (BVF) at 5 years. RESULTS Compared with SAVR, the SAPIEN-XT TAVR cohort had a significantly higher 5-year exposure adjusted incidence rates (per 100 patient-years) of SVD (1.61 ± 0.24% vs. 0.63 ± 0.16%), SVD-related BVF (0.58 ± 0.14% vs. 0.12 ± 0.07%), and all-cause (structural or nonstructural) BVF (0.81 ± 0.16% vs. 0.27 ± 0.10%) (p ≤ 0.01 for all). The 5-year rates of SVD (0.68 ± 0.18% vs. 0.60 ± 0.17%; p ¼ 0.71), SVD-related BVF (0.29 ± 0.12% vs. 0.14 ± 0.08%; p ¼ 0.25), and all-cause BVF (0.60 ± 0.15% vs. 0.32 ± 0.11%; p ¼ 0.32) in SAPIEN 3 TAVR were not significantly different to a propensity score matched SAVR cohort. The 5-year rates of SVD and SVD-related BVF were significantly lower in SAPIEN 3 versus SAPIEN XT TAVR matched cohorts. CONCLUSIONS Compared with SAVR, the second-generation SAPIEN XT balloon-expandable valve has a higher 5-year rate of SVD, whereas the third-generation SAPIEN 3 has a rate of SVD that was not different from SAVR. (The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves - PII A [PARTNERII A]; NCT01314313; The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - PARTNER II - PARTNERII - S3 Intermediate [PARTNERII S3i]; NCT03222128)
  • PublicationAccès libre
    Contrast-enhanced computed tomography assessment of aortic stenosis.
    (2021-01-29) Timothy Robert, Graham Cartlidge; Guzzetti, Ezequiel; Bing, Rong; Couture, Christian; Kwiecinski, Jacek; Pibarot, Philippe; Clavel, Marie-Annick; Pawade, Tania; Doris, Mhairi K; Adamson, Philip D; Massera, Daniele; Lembo, Maria; Peeters, Frederique E. C. M.; Berman, Daniel S; Dey, Damini; Slomka, Piotr; Newby, David E; Dweck, Marc R
    Abstract Objectives Non-contrast CT aortic valve calcium scoring ignores the contribution of valvular fibrosis in aortic stenosis. We assessed aortic valve calcific and non-calcific disease using contrast-enhanced CT. Methods This was a post hoc analysis of 164 patients (median age 71 (IQR 66–77) years, 78% male) with aortic stenosis (41 mild, 89 moderate, 34 severe; 7% bicuspid) who underwent echocardiography and contrast-enhanced CT as part of imaging studies. Calcific and non-calcific (fibrosis) valve tissue volumes were quantified and indexed to annulus area, using Hounsfield unit thresholds calibrated against blood pool radiodensity. The fibrocalcific ratio assessed the relative contributions of valve fibrosis and calcification. The fibrocalcific volume (sum of indexed non-calcific and calcific volumes) was compared with aortic valve peak velocity and, in a subgroup, histology and valve weight. Results Contrast-enhanced CT calcium volumes correlated with CT calcium score (r=0.80, p<0.001) and peak aortic jet velocity (r=0.55, p<0.001). The fibrocalcific ratio decreased with increasing aortic stenosis severity (mild: 1.29 (0.98–2.38), moderate: 0.87 (1.48–1.72), severe: 0.47 (0.33–0.78), p<0.001) while the fibrocalcific volume increased (mild: 109 (75–150), moderate: 191 (117–253), severe: 274 (213–344) mm3/cm2). Fibrocalcific volume correlated with ex vivo valve weight (r=0.72, p<0.001). Compared with the Agatston score, fibrocalcific volume demonstrated a better correlation with peak aortic jet velocity (r=0.59 and r=0.67, respectively), particularly in females (r=0.38 and r=0.72, respectively). Conclusions Contrast-enhanced CT assessment of aortic valve calcific and non-calcific volumes correlates with aortic stenosis severity and may be preferable to non-contrast CT when fibrosis is a significant contributor to valve obstruction.
  • PublicationAccès libre
    Effect of regional upper septal hypertrophy on echocardiographic assessment of left ventricular mass and remodeling in aortic stenosis
    (ScienceDirect, 2020-10-14) Guzzetti, Ezequiel; Garcia, Julio; Larose, Éric; Shen, Mylène; Le Ven, Florent; Bédard, Élisabeth; Capoulade, Romain; Annabi, Mohamed Salah; Pibarot, Philippe; Clavel, Marie-Annick; Tastet, Lionel; Arsenault, Marie
    Background: Transthoracic echocardiography (TTE) is the reference method for evaluation of aortic stenosis (AS), and it is extensively used to quantitate left ventricular (LV) mass and volumes. Regional upper septal hypertrophy (USH) or septal bulge is a frequent finding in patients with AS and may lead to overestimation of LV mass when using linear measurements. The objective of this study was to compare estimates of LV mass obtained by two-dimensional transthoracic echocardiographic LV dimensions measured at different levels of the LV cavity with those obtained by cardiovascular magnetic resonance (CMR). Methods: One hundred six patients (mean age, 63 ± 15 years; 68% men) with AS were included in this subanalysis of the PROGRESSA study. Two-dimensional transthoracic echocardiographic measurements of LV dimensions were obtained at the basal level (BL; as recommended in guidelines), immediately below the septal bulge (BSB), and at a midventricular level (ML). Regional USH was defined as a basal interventricular septal thickness ≥ 13 mm and >1.3 times the thickness of the septal wall at the ML. Agreement between transthoracic echocardiographic and CMR measures was evaluated using Bland-Altman analysis. Results: The distribution of AS severity was mild in 23%, moderate in 57%, and severe in 20% of patients. Regional USH was present in 28 patients (26%). In the whole cohort, two-dimensional TTE overestimated LV mass (bias: BL, +60 ± 31 g; BSB, +59 ± 32 g; ML, +54 ± 32 g; P = .02). The biplane Simpson method slightly but significantly underestimated LV end-diastolic volume (bias -10 ± 20 mL, P < .001) compared with CMR. Overestimation of LV mass was more marked in patients with USH when measuring at the BL and was significantly lower when measuring LV dimensions at the ML (P < .025 vs BL and BSB). Conclusions: Two-dimensional TTE systematically overestimated LV mass and underestimated LV volumes compared with CMR. However, the bias between TTE and CMR was less important when measuring at the ML. Measurements at the BL as suggested in guidelines should be avoided, and measurements at the ML should be preferred in patients with AS, especially in those with USH.
  • PublicationRestreint
    Left ventricular asymmetric remodeling and subclinical left ventricular dysfunction in patients with calcific aortic valve stenosis : results from a subanalysis of the PROGRESSA study
    (Elsevier Science Publishers, 2021-03-13) Clisson, Marine; Guzzetti, Ezequiel; Bernard, Jérémy; Larose, Éric; Shen, Mylène; Bédard, Élisabeth; Côté, Nancy; Capoulade, Romain; Pibarot, Philippe; Clavel, Marie-Annick; Tastet, Lionel; Arsenault, Marie
    Background: LV asymmetric remodeling (LVAR) is a feature commonly found in AS patients and it is presumed to be mainly related to the severity of valve stenosis. The aim of this study was to determine the associated factors and impact on left ventricular (LV) systolic function of LVAR in patients with mild and moderate aortic valve stenosis (AS). Methods: Clinical, Doppler-echocardiographic and computed-tomographic data of 155 AS patients with preserved LV ejection fraction (≥50%) prospectively recruited in the PROGRESSA study (NCT01679431) were analyzed. LVAR was defined as a septal wall thickness ≥ 13 mm and a ratio of septal/posterior wall thickness > 1.5. LV global longitudinal strain (LV-GLS) was available in 129 patients. Plasma levels of N-terminal natriuretic B-type peptides (Nt-proBNP) were also measured. Results: Mean age was 63 ± 15 years (70% men). LVAR was present in 21% (n = 33) of patients. A series of nested multivariate analysis revealed that age was the only factor associated with LVAR (all p ≤ 0.03). Additionally, these patients had higher baseline Nt-proBNP ratio (median [25–75 percentiles]: 1.04 [0.66–2.41] vs. 0.65 [0.33–1.19], p = 0.02), and significantly reduced LV-GLS (17.9[16.6–19.5] vs. 19.3[17.4–20.7] |%|, p = 0.04). A 1:1 matched analysis showed a significant association of LVAR with reduced LV-GLS (17.9[16.6–19.5] vs. 19.8[18.1–20.7] |%|, p = 0.02) and elevated Nt-proBNP (134[86–348] vs. 83[50–179]pg/ml, p = 0.03). Multivariable analysis also revealed that LVAR remains significantly associated with reduced LV-GLS (p = 0.03) and elevated Nt-proBNP (p = 0.001). LVAR was significantly associated with increased risk of major adverse cardiac events and death (Hazard ratio [95% confidence interval]: 2.32[1.28–4.22], p = 0.006). Conclusions: LVAR was found in ~20% of patients with mild or moderate AS and was not related to the degree of AS severity or concomitant comorbidities, but rather to older age. LVAR was significantly associated with reduced LV longitudinal systolic function, increased Nt-proBNP levels, and higher risk of major adverse events and death. These findings provide support for closer clinical and echocardiographic surveillance of patients harboring this adverse LV remodeling feature.
  • PublicationRestreint
    Estimation of stroke volume and aortic valve area in patients with aortic stenosis : a comparison of echocardiography versus cardiovascular magnetic resonance
    (Elsevier, 2020-06-21) Guzzetti, Ezequiel; Garcia, Julio; Larose, Éric; Le Ven, Florent; Capoulade, Romain; Pibarot, Philippe; Bédard, Élisabeth; Clavel, Marie-Annick; Tastet, Lionel; Arsenault, Marie
    Background: In aortic stenosis, accurate measurement of left ventricular stroke volume (SV) is essential for the calculation of aortic valve area (AVA) and the assessment of flow status. Current American Society of Echocardiography and European Association of Cardiovascular Imaging guidelines suggest that measurements of left ventricular outflow tract diameter (LVOTd) at different levels (at the annulus vs 5 or 10 mm below) yield similar measures of SV and AVA. The aim of this study was to assess the effect of the location of LVOTd measurement on the accuracy of SV and AVA measured on transthoracic echocardiography (TTE) compared with cardiovascular magnetic resonance (CMR). Methods: One hundred six patients with aortic stenosis underwent both TTE and CMR. SV was estimated on TTE using the continuity equation with LVOTd measurements at four locations: at the annulus and 2, 5, and 10 mm below annulus. SV was also determined on CMR using phase contrast acquired in the aorta (SVCMR-PC), and a hybrid AVACMR-PC was calculated by diving SVCMR-PC by the transthoracic echocardiographic Doppler aortic velocity-time integral. Comparison between methods was made using Bland-Altman analysis. Results: Compared with the referent method of phase-contrast CMR for the estimation of SVCMR-PC and AVACMR-PC (SVCMR-PC 83 6 16 mL, AVACMR-PC 1.27 6 0.35 cm2 ), the best agreement was obtained by measuring LVOTd at the annulus or 2 mm below (P = NS), whereas measuring 5 and 10 mm below the annulus resulted in significant underestimation of SV and AVA by up to 15.9 6 17.3 mL and 0.24 6 0.28 cm2 , respectively (P < .01 for all). Accuracy for classification of low flow was best at the annulus (86%) and 2 mm below (82%), whereas measuring 5 and 10 mm below the annulus significantly underperformed (69% and 61%, respectively, P < .001). Conclusions: Measuring LVOTd at the annulus or very close to it provides the most accurate measures of SV and AVA, whereas measuring LVOTd 5 or 10 mm below significantly underestimates these parameters and leads to significant overestimation of the severity of aortic stenosis and prevalence of low-flow status.