Pour savoir comment effectuer et gérer un dépôt de document, consultez le « Guide abrégé – Dépôt de documents » sur le site Web de la Bibliothèque. Pour toute question, écrivez à corpus@ulaval.ca.
 

Personne :
Bertrand, Olivier

En cours de chargement...
Photo de profil

Adresse électronique

Date de naissance

Projets de recherche

Structures organisationnelles

Fonction

Nom de famille

Bertrand

Prénom

Olivier

Affiliation

Université Laval. Faculté de médecine

ISNI

ORCID

Identifiant Canadiana

ncf11860491

person.page.name

Résultats de recherche

Voici les éléments 1 - 5 sur 5
  • PublicationRestreint
    Incidence, predictive factors, and prognostic value of myocardial injury following uncomplicated transcatheter aortic valve implantation.
    (Elsevier Biomedical, 2011-05-17) Bertrand, Olivier; Gutiérrez, Marcos; Dumont, Éric; De Larochellière, Robert; Larose, Éric; Côté, Mélanie; Villeneuve, Jacques; Rodés-Cabau, Josep; Bagur, Rodrigo Hernan; Doyle, Daniel; Manazzoni, Juan; Pibarot, Philippe
    OBJECTIVES: This study sought to: 1) determine the incidence, degree, and timing of the rise in serum cardiac markers of myocardial injury associated with uncomplicated transcatheter aortic valve implantation (TAVI); and 2) evaluate the predictive factors and prognostic value of myocardial injury associated with TAVI. BACKGROUND: Very few data exist on the occurrence and clinical relevance of myocardial injury during TAVI procedures. METHODS: A total of 101 patients who underwent successful TAVI (transfemoral [TF] approach, n = 38; transapical [TA] approach, n = 63) were included. Creatine kinase-MB (CK-MB) and cardiac troponin T (cTnT) levels were determined at baseline and at 6 to 12, 24, 48, and 72 h following TAVI. RESULTS: TAVI was associated with some degree of myocardial injury in 99% of the patients (TF: 97%, TA: 100%) as determined by a rise in cTnT (maximal value, 0.48 µg/l, interquartile range [IQR]: 0.24 to 0.82 µg/l) and in 77% of the patients (TF: 47%, TA: 95%) as determined by a rise in CK-MB (maximal value, 18.6 µg/l; IQR: 11.0 to 27.4 µg/l). TA approach and baseline renal dysfunction were associated with a higher increase in biomarkers of myocardial injury (p < 0.01 for both). A larger myocardial injury was associated with a smaller improvement of left ventricular ejection fraction (LVEF) (p < 0.01). The degree of rise in cTnT was an independent predictor of cardiac mortality at 9 ± 10 months of follow-up (hazard ratio: 1.14 per each increase of 0.1 µg/l, 95% confidence interval: 1.02 to 1.28, p = 0.028). CONCLUSIONS: TAVI was systematically associated with some degree of myocardial injury, with TA approach and baseline renal dysfunction determining a higher increase in biomarkers of myocardial injury. A greater degree of myocardial injury was associated with less improvement in LVEF and a higher cardiac mortality at follow-up.
  • PublicationRestreint
    Performance-based functional assessment of patients undergoing transcatheter aortic valve implantation
    (Elsevier, 2011-04-01) Bertrand, Olivier; Dumont, Éric; De Larochellière, Robert; Villeneuve, Jacques; Rodés-Cabau, Josep; Bagur, Rodrigo Hernan; Côté, Mélanie; Doyle, Daniel; Poirier, Paul; Pibarot, Philippe; Gutiérrez-Marcos, José; Clavel, Marie-Annick
    Background: Very few data exist on the functional evaluation of patients with severe symptomatic aortic stenosis undergoing transcatheter aortic valve implantation (TAVI). The aims of this prospective study were (1) to evaluate the Duke Activity Status Index (DASI) as a measure of functional status pre-TAVI and post-TAVI, (2) to determine the clinical parameters associated with DASI changes after TAVI, and (3) to compare functional status as evaluated by DASI and the New York Heart Association (NYHA) class with exercise capacity as evaluated by the 6-minute walk test (6MWT) in such patients. Methods: A total of 76 patients (80 ± 8 years old) who underwent successful TAVI were included. All patients completed the DASI self-questionnaire at baseline and at 6 months after TAVI, and 46 patients also performed a 6MWT. Results: The mean DASI increased from 10.3 ± 5.4 to 16.3 ± 8.3 at 6 months after TAVI (P < .0001). However, the DASI did not change or even decreased to some extent in 30% of patients after TAVI. Renal dysfunction as evaluated by the estimated glomerular filtration rate was identified as the independent predictor of DASI impairment after TAVI (OR 1.7 for each decrease in estimated glomerular filtration rate of 10 mL/min/1.73 m(2), 95% CI 1.3-2.3, P = .005). The mean distance walked increased from 165.9 ± 77.6 to 211.8 ± 78.7 m (P = .0001) at follow-up. The DASI showed a good correlation with the distance walked at baseline (r = 0.55, P < .0001) and at follow-up (r = 0.66, P < .0001). The NYHA class improved to some degree in all but 5 patients; however, the NYHA class did not correlate with the results of DASI and the 6MWT. Conclusions: Transcatheter aortic valve implantation was associated with a significant increase in functional status at 6-month follow-up as evaluated by the DASI, although no improvement was observed in about one third of patients. The presence of baseline renal dysfunction better determined this lack of improvement in functional status. The DASI, but not the NYHA class, correlated with distance walked in the 6MWT. These results suggest that the DASI might become a useful tool for evaluating both candidates for and the impact of TAVI procedures.
  • PublicationRestreint
    Electrocardiographic changes and clinical outcomes after transapical aortic valve implantation
    (C. V. Mosby Co., 2009-08-01) Gutiérrez-Marcos, José; Bertrand, Olivier; Lemieux, Jérôme; Dumont, Éric; De Larochellière, Robert; Côté, Mélanie; Villeneuve, Jacques; Rodés-Cabau, Josep; Bergeron, Sébastien; Bagur, Rodrigo Hernan; Doyle, Daniel; Poirier, Paul; Pibarot, Philippe; Clavel, Marie-Annick
    Background : Transapical aortic valve implantation (TAVI) for the treatment of severe aortic stenosis requires the insertion of a large catheter through the left ventricular apex. However, the electrocardiographic (ECG) changes associated with the incision and repair of the left ventricular apex and the potential damage to the conduction system caused by implanting a balloon-expandable valve in aortic position are not known. The objective of our study was to determine the incidence, type, and timing of ECG changes associated with TAVI. Methods : The standard 12-lead ECGs of 33 consecutive patients (mean age 81 ± 9 years, 13 men) diagnosed with symptomatic severe aortic stenosis (valve area 0.62 ± 0.16 cm2) who underwent TAVI with an Edwards-SAPIEN valve were analyzed at baseline (within 24 hours before the procedure), immediately (within 6 hours) after the procedure, at hospital discharge, and at 1-month follow-up. Results : There were no procedural deaths, and 30-day mortality was 6%. The incidence of complete left ventricular branch block (LBBB) and left anterior hemiblock (LAHB) increased from 9% and 3% at baseline to 27% and 36% after the procedure, respectively (P < .03 for both). A lower (ventricular) position of the valve relative to the hinge point of the anterior mitral leaflet was associated with a higher incidence of new LBBB (35% vs 0%, P = .029); and a greater valve size–aortic annulus ratio, with the occurrence of new LAHB (1.20 ± 0.07 vs 1.14 ± 0.06, P = .021). At 1-month follow-up, the rate of LBBB and LAHB decreased to 13% and 10%, respectively (P = not significant compared with baseline). There were no cases of new atrioventricular block, and no patient needed pacemaker implantation. Transient (<48 hours) ST-elevation changes, mostly in the anterior and/or lateral leads, occurred in 6 patients (18%) immediately after the procedure; but only 1 of these patients presented new Q waves at 1-month follow-up. Conclusions : Transapical aortic valve implantation was associated with a significant but transient (<1 month) increase in LBBB and LAHB, with no patient requiring pacemaker implantation. These changes were partially related to both lower (more ventricular) valve positioning and greater valve oversizing. Transient (<48 hours) ST-segment elevation changes occurred in about one fifth of the patients after the procedure, but only a minority developed new Q waves in the ECG.
  • PublicationRestreint
    Exercise capacity in patients with severe symptomatic aortic stenosis before and six months after transcatheter aortic valve implantation
    (Elsevier, 2011-07-15) Bertrand, Olivier; Dumont, Éric; De Larochellière, Robert; Côté, Mélanie; Rodés-Cabau, Josep; Bagur, Rodrigo Hernan; Doyle, Daniel; Poirier, Paul; Pibarot, Philippe
    Few data exist on the use of the 6-minute walk test (6MWT) to measure the exercise capacity of patients with severe symptomatic aortic stenosis considered at very high surgical risk. The objectives of the present prospective study were (1) to determine the feasibility and safety of the 6MWT as a measure of exercise capacity before and after transcatheter aortic valve implantation (TAVI), and (2) to determine the clinical and hemodynamic parameters associated with the exercise capacity changes in such patients. A total of 64 patients (age 80 ± 8 years, logistic European System for Cardiac Operative Risk Evaluation score 21 ± 15%, Society of Thoracic Surgeons' score 7.5 ± 3.9%) who had undergone successful TAVI were included. The 6MWT was performed within the month before TAVI and at the 6-month follow-up visit. The mean distance walked increased from 165.3 ± 79.7 to 231.7 ± 88.9 m (p <0.0001); however, up to 25% of the patients did not improve or even decreased their exercise capacity. After adjustment for the baseline distance walked, multilinear regression analysis showed that a greater degree of renal dysfunction, as evaluated by the serum creatinine levels (r(2) = 0.05, p = 0.03), lower postprocedural hemoglobin values (r(2) = 0.13, p = 0.0012), and a longer hospitalization length (r(2) = 0.08, p = 0.007) were associated with lower improvement in exercise capacity. In conclusion, exercise capacity, as evaluated by the 6MWT, was very poor in patients with severe symptomatic aortic stenosis considered at very high surgical risk. TAVI was associated with a significant increase in exercise capacity, although no improvement was observed in 1/4 of the patients. A greater degree in renal dysfunction, lower postprocedural hemoglobin values, and longer hospitalization stay were predictors of lower improvement in exercise capacity after TAVI. These results suggest that the 6MWT might become an important tool as a part of the evaluation process for TAVI candidates.
  • PublicationRestreint
    Usefulness of TEE as the primary imaging technique to guide transcatheter transapical aortic valve implantation
    (American College of Cardiology Foundation, 2011-02-01) Bertrand, Olivier; Lemieux, Jérôme; Dumont, Éric; De Larochellière, Robert; Côté, Mélanie; Villeneuve, Jacques; Rodés-Cabau, Josep; Bergeron, Sébastien; Bagur, Rodrigo Hernan; Doyle, Daniel; Pibarot, Philippe
    Objectives: The aim of this study was to: 1) determine the usefulness of transesophageal echocardiography (TEE) as the primary technique to guide transapical (TA) transcatheter aortic valve implantation (TAVI); and 2) to compare TEE with angiography as the primary imaging modality for TA-TAVI guidance. Background: TEE has been routinely used as an adjunct to angiography during TA-TAVI procedures, but very few data exist on the use of TEE as the primary imaging technique guiding TA-TAVI. Methods: One hundred consecutive high-risk patients (mean age 79 ± 9 years, mean logistic EuroSCORE: 25.8 ± 17.6%) who underwent TA-TAVI in our center were included. The Edwards valve was used in all cases, and all procedures were performed in an operating room without hybrid facilities. The TA-TAVI was primarily guided by angiography in the first 25 patients (A-TAVI group) and by TEE in the last 75 patients (TEE-TAVI group). Procedural, 30-day, and follow-up results were evaluated. Results: No differences were observed between groups at baseline except for a higher (p = 0.001) prevalence of moderate or severe mitral regurgitation in the TEE-TAVI group. The procedure was successful in 97.3% and 100% of the patients in the TEE-TAVI and A-TAVI groups, respectively (p = 1.0), and a lower contrast volume was used in the TEE-TAVI group (12 [5 to 20] ml vs. 40 [20 to 50] ml, p < 0.0001). There were no differences between groups in the occurrence of valve malposition needing a second valve (TEE-TAVI: 5.3%; A-TAVI: 4%; p = 1.0) or valve embolization (TEE-TAVI: 1.3%; A-TAVI: 4%; p = 0.44). The results regarding post-procedural valve hemodynamic status and aortic regurgitation were similar between groups. The survival rates at 30-day and 1-year follow-up were 87% and 75% in the TEE-group and 88% and 84% in the A-TAVI group, respectively (log-rank = 0.49). Conclusions: TEE-TAVI was associated with similar acute and midterm results as A-TAVI and significantly reduced contrast media use during the procedures. These results suggest the feasibility and safety of performing TA-TAVI procedures in an operating room without hybrid facilities, but larger studies are needed to confirm these findings.