Impact of prosthesis-patient mismatch on the regression of secondary mitral regurgitation after isolated aortic valve replacement with a bioprosthetic valve in patients with severe aortic stenosis

Authors: Angeloni, Emiliano; Melina, Giovanni; Pibarot, Philippe; Benedetto, Umberto; Refice, Simone; Ciavarella, Giuseppino M.; Roscitano, Antonino; Sinatra, Riccardo; Pepper, John (John Robert)
Abstract: OBJECTIVES: This study sought to evaluate the incidence, predictive factors, and prognostic value of new-onset atrial fibrillation (NOAF) following transcatheter aortic valve implantation (TAVI). BACKGROUND: Very few data exist on the occurrence of NOAF following TAVI. METHODS: A total of 138 consecutive patients with no prior history of atrial fibrillation (AF) underwent TAVI with a balloon-expandable valve. Patients were on continuous electrocardiogram monitoring until hospital discharge, and NOAF was defined as any episode of AF lasting >30 s. All clinical, echocardiographic, procedural, and follow-up data were prospectively collected. RESULTS: NOAF occurred in 44 patients (31.9%) at a median time of 48 h (interquartile range: 0 to 72 h) following TAVI. The predictive factors of NOAF were left atrial (LA) size (odds ratio [OR]: 1.21 for each increase in 1 mm/m(2), 95% confidence interval [CI]: 1.09 to 1.34, p < 0.0001) and transapical approach (OR: 4.08, 95% CI: 1.35 to 12.31, p = 0.019). At 30-day follow-up, NOAF was associated with a higher rate of stroke/systemic embolism (13.6% vs. 3.2%, p = 0.021, p = 0.047 after adjustment for baseline differences between groups), with no differences in mortality rate between groups (NOAF: 9.1%, no-NOAF: 6.4%, p = 0.57). At a median follow-up of 12 months (interquartile range: 5 to 20 months), a total of 27 patients (19.6%) had died, with no differences between the NOAF (15.9%) and no-NOAF (21.3%) groups, p = 0.58. The cumulative rate of stroke and stroke/systemic embolism at follow-up were 13.6% and 15.9%, respectively, in the NOAF group versus 3.2% in the no-NOAF group (p = 0.039, adjusted p = 0.037 for stroke; p = 0.020, adjusted p = 0.023 for stroke/systemic embolism). CONCLUSIONS: NOAF occurred in about one-third of the patients with no prior history of AF undergoing TAVI and its incidence was increased in patients with larger LA size and those undergoing transapical TAVI. NOAF was associated with a higher rate of stroke/systemic embolism, but not a higher mortality, at 30 days and at 1-year follow-up.
Document Type: Article de recherche
Issue Date: 1 January 2012
Open Access Date: Restricted access
Document version: VoR
Permalink: http://hdl.handle.net/20.500.11794/7814
This document was published in: Circulation: Cardiovascular Imaging, Vol. 5 (1), 36-42 (2012)
https://doi.org/10.1161/CIRCIMAGING.111.967612
Lippincott Williams & Wilkins
Alternative version: 10.1161/CIRCIMAGING.111.967612
22138006
Collection:Articles publiés dans des revues avec comité de lecture

Files in this item:
SizeFormat 
Angeloni2012-13058.pdf
468.58 kBAdobe PDF    Request a copy
All documents in CorpusUL are protected by Copyright Act of Canada.