Electrocardiographic changes and clinical outcomes after transapical aortic valve implantation

Authors: Gutiérrez-Marcos, José; Rodés-Cabau, JosepBagur, Rodrigo HernanDoyle, DanielDe Larochellière, RobertBergeron, SébastienLemieux, JérômeVilleneuve, JacquesCôté, MélanieBertrand, OlivierPoirier, PaulClavel, Marie-AnnickPibarot, PhilippeDumont, Éric
Abstract: Background : Transapical aortic valve implantation (TAVI) for the treatment of severe aortic stenosis requires the insertion of a large catheter through the left ventricular apex. However, the electrocardiographic (ECG) changes associated with the incision and repair of the left ventricular apex and the potential damage to the conduction system caused by implanting a balloon-expandable valve in aortic position are not known. The objective of our study was to determine the incidence, type, and timing of ECG changes associated with TAVI. Methods : The standard 12-lead ECGs of 33 consecutive patients (mean age 81 ± 9 years, 13 men) diagnosed with symptomatic severe aortic stenosis (valve area 0.62 ± 0.16 cm2) who underwent TAVI with an Edwards-SAPIEN valve were analyzed at baseline (within 24 hours before the procedure), immediately (within 6 hours) after the procedure, at hospital discharge, and at 1-month follow-up. Results : There were no procedural deaths, and 30-day mortality was 6%. The incidence of complete left ventricular branch block (LBBB) and left anterior hemiblock (LAHB) increased from 9% and 3% at baseline to 27% and 36% after the procedure, respectively (P < .03 for both). A lower (ventricular) position of the valve relative to the hinge point of the anterior mitral leaflet was associated with a higher incidence of new LBBB (35% vs 0%, P = .029); and a greater valve size–aortic annulus ratio, with the occurrence of new LAHB (1.20 ± 0.07 vs 1.14 ± 0.06, P = .021). At 1-month follow-up, the rate of LBBB and LAHB decreased to 13% and 10%, respectively (P = not significant compared with baseline). There were no cases of new atrioventricular block, and no patient needed pacemaker implantation. Transient (<48 hours) ST-elevation changes, mostly in the anterior and/or lateral leads, occurred in 6 patients (18%) immediately after the procedure; but only 1 of these patients presented new Q waves at 1-month follow-up. Conclusions : Transapical aortic valve implantation was associated with a significant but transient (<1 month) increase in LBBB and LAHB, with no patient requiring pacemaker implantation. These changes were partially related to both lower (more ventricular) valve positioning and greater valve oversizing. Transient (<48 hours) ST-segment elevation changes occurred in about one fifth of the patients after the procedure, but only a minority developed new Q waves in the ECG.
Document Type: Article de recherche
Issue Date: 1 August 2009
Open Access Date: Restricted access
Document version: VoR
Permalink: http://hdl.handle.net/20.500.11794/6488
This document was published in: The American heart journal, Vol. 158 (2), 302–308 (2009)
https://doi.org/10.1016/j.ahj.2009.05.029
C. V. Mosby Co.
Alternative version: 10.1016/j.ahj.2009.05.029
19619709
Collection:Articles publiés dans des revues avec comité de lecture

Files in this item:
SizeFormat 
Gutierrez2009-11667.pdf
212.21 kBAdobe PDF    Request a copy
All documents in CorpusUL are protected by Copyright Act of Canada.