Aortic valve area calculation in aortic stenosis by CT and Doppler echocardiography

Authors: Clavel, Marie-Annick; Malouf, Joseph; Messika-Zeitoun, David; Araoz, Philip A.; Michelena, Hector I.; Enriquez-Sarano, Maurice
Abstract: Objectives The aim of this study was to verify the hypothesis that multidetector computed tomography (MDCT) is superior to echocardiography for measuring the left ventricular outflow tract (LVOT) and calculating the aortic valve area (AVA) with regard to hemodynamic correlations and survival outcome prediction after a diagnosis of aortic stenosis (AS). Background MDCT demonstrated that the LVOT is noncircular, casting doubt on the AVA measurement by 2-dimensional (2D) echocardiography. Methods A total of 269 patients (76 ± 11 years of age, 61% men) with isolated calcific AS (mean gradient 44 ± 18 mm Hg; ejection fraction 58 ± 15%) underwent Doppler echocardiography and MDCT within the same episode of care. AVA was calculated by echocardiography (AVAEcho) and by MDCT (AVACT) using each technique measurement of LVOT area. In the subset of patients undergoing dynamic 4-dimensional MDCT (n = 135), AVA was calculated with the LVOT measured at 70% and 20% of the R-R interval and measured by planimetry (AVAPlani). Results Phasic measurements of the LVOT by MDCT yielded slight differences in eccentricity and size (all p < 0.001) but with excellent AVA correlation (r = 0.92, p < 0.0001) and minimal bias (0.05 cm2), whereas the AVAPlani showed poor correlations with all other methods (all r values <0.58). AVACT was larger than AVAEcho (difference 0.12 ± 0.16 cm2; p < 0.0001) but did not improve outcome prediction. Correlation gradient-AVA was slightly better with AVAEcho than AVACT (r = -0.65 with AVAEcho vs. -0.61 with AVACT; p = 0.01), and discordant gradient-AVA was not reduced. For long-term survival, after multivariable adjustment, AVAEcho or AVACT were independently predictive (hazard ratio [HR]: 1.26, 95% confidence interval [CI]: 1.13 to 1.42; p < 0.0001 or HR: 1.18, 95% CI: 1.09 to 1.29 per 0.10 cm2 decrease; p < 0.0001) with a similar prognostic value (p = 0.80). Thresholds for excess mortality differed between methods: AVAEcho =1.0 cm2 (HR: 4.67, 95% CI: 2.22 to 10.50; p < 0.0001) versus AVACT =1.2 cm2 (HR: 3.16, 95% CI: 1.64 to 6.43; p = 0.005), with simple translation of spline-curve analysis. Conclusions Head-to-head comparison of MDCT and Doppler echocardiography refutes the hypothesis of MDCT superiority for AVA calculation. AVACT is larger than AVAEcho but does not improve the correlation with transvalvular gradient, the concordance gradient-AVA, or mortality prediction compared with AVAEcho. Larger cut-point values should be used for severe AS if AVACT (<1.2 cm2) is measured versus AVAEcho (<1.0 cm2).
Document Type: Article de recherche
Issue Date: 9 March 2015
Open Access Date: Restricted access
Document version: VoR
Permalink: http://hdl.handle.net/20.500.11794/2028
This document was published in: JACC : Cardiovascular Imaging, Vol. 8 (3), 248–257 (2015)
http://dx.doi.org/10.1016/j.jcmg.2015.01.009
Elsevier
Alternative version: 10.1016/j.jcmg.2015.01.009
http://www.ncbi.nlm.nih.gov/pubmed/25772832
Collection:Articles publiés dans des revues avec comité de lecture

Files in this item:
SizeFormat 
Clavel2015-14617.pdf
898.04 kBAdobe PDF    Request a copy
All documents in CorpusUL are protected by Copyright Act of Canada.